Applications:
– Potable water storage tanks and reservoirs
– Wastewater treatment facilities and drainage channels
– Bridge decks and marine structures
– Any concrete surface exposed to constant moisture
– Protective coating for exposed reinforcement
Key Advantages:
✓ Exceptional chemical resistance
✓ Superior adhesion with deep penetration into concrete pores
✓ High elasticity to accommodate substrate movement
✓ Outstanding tensile, flexural, and compressive strength
✓ Synergistic hydration mechanism between Component A (cementitious) and Component B (polymer)
✓ Protects reinforcement and prevents surface freeze-thaw damage
✓ Creates monolithic, non-leaching barrier
Coverage Rate:
1-3 kg/m² for 3mm thickness (varies by substrate)
Mixing & Application:
1. Mixing Procedure:
– Ratio: 4 parts Component A + 1 part Component B
– Mix to uniform consistency (water may be added to adjust viscosity)
– Pot life: 1-2 hours (temperature dependent)
2. Surface Preparation:
– Remove all loose particles, oils, and weak concrete
– Pre-fill large cracks/voids with product
– Saturate substrate before application
3. Application Guidelines:
– Maximum single-layer thickness: 5mm
– Ambient temperature range: 10-35°C (50-95°F)
– Maintain surface moisture during curing
Technical Specifications:
Component A:
– Form: Powder
– Color: Gray
– Density: 1.75 g/cm³
– Shelf Life: 6 months in original packaging
– Packaging: 20kg moisture-resistant bags
Component B:
– Form: Liquid
– Color: White
– Density: 1.01 g/cm³
– Water-miscible
– Shelf Life: 6 months in original packaging
– Packaging: 5kg, 10kg, 20kg containers or 220kg drums
Cleanup:
– Clean tools immediately with water
– Cured material requires mechanical removal
Safety & Compliance:
⚠ PPE REQUIREMENTS:
– Chemical-resistant gloves
– Safety goggles
– Avoid inhalation of dust
– First Aid: Flush exposed areas with water for 15 minutes
– Do not mix with other chemicals
Environmental:
– Do not dispose in waterways or soil
– Contains no heavy metals or VOCs
Quality Certification:
Manufactured under ISO 9001 quality management system with NSF/ANSI 61 certification for potable water contact.